Appearance requirements
The surface of the equipment should be sprayed evenly, with the same color, and there should be no flow marks, blistering, paint leakage, or peeling on the surface.
The appearance of the equipment is neat and beautiful, without obvious hammer marks and unevenness. The panel meters, switches, indicator lights, and signs should be installed firmly and upright.
The welding of the equipment shell and frame should be firm, without obvious deformation or burn-through defects.
Key points of construction and installation
It is not easy to install the ultraviolet generator on the outlet pipe close to the water pump to prevent the quartz glass tube and the lamp tube from being damaged by the water hammer when the pump is stopped.
The ultraviolet generator should be installed strictly in accordance with the direction of water inlet and outlet.
The ultraviolet generator should have a foundation higher than the ground of the building, and the foundation should not be less than 100mm higher than the ground.
The ultraviolet generator and its connecting pipes and valves should be firmly fixed, and the ultraviolet generator should not be allowed to bear the weight of the pipes and accessories.
The installation of the ultraviolet generator should be convenient for disassembly, repair and maintenance, and no materials that affect water quality and sanitation should be used at all pipe connections.
Frequently Asked Questions
The surface must be sprayed evenly with a consistent color. It should be completely free of flow marks, blistering, paint leakage, or peeling, and the welding of the shell and frame must be firm without deformation or burn-through.
Installing it close to the pump outlet exposes it to water hammer when the pump stops. This pressure surge can easily damage the fragile quartz glass tube and the lamp tube inside the generator.
The ultraviolet generator must be installed on a foundation that is higher than the building's floor level. The height of this foundation should not be less than 100mm.
No, the generator must not bear the weight of the pipes and accessories. The generator, along with all connecting pipes and valves, must be independently and firmly fixed to prevent structural strain.
Any materials that could negatively affect water quality and sanitation must not be used at any of the pipe connections. Additionally, the setup should allow for easy disassembly, repair, and routine maintenance.